RCP 101 Decorator-Style Remote Control Panel for SMP Series Products
- Provide a Decorator-style remote control panel for the purpose of remotely controlling, monitoring and connecting USB storage when paired with an Extron SMP Series Streaming Media Processor.
- Connection Requirements
- USB Requirements
- Provide one rear accessible mini USB type B port mounted at a right angle to the faceplate.
- Provide one front accessible USB type A receptacle
- Support 12V power connection
- Provide one rear captive screw connection for 12VDC power
- USB Requirements
- Mounting requirements
- Device shall have the ability to be mounted directly in a wall, lectern, or other flat surface and shall be able to be secured using the supplied mud ring and hardware.
- Device shall have the ability to be mounted to the surface of a wall using an optional wall box.
- Device shall include both white and black faceplates.
- Cabling requirements
- Device shall include a 15 foot (4.5 meters) USB A to mini B cable for direct connection to an Extron SMP series product.
- Device shall include a 15 foot (4.5 meters) DC power cable for direct connection to an Extron SMP 111 Streaming media Processor, or external 12VDC power supply
- Device may be optionally extended up to 330 feed (100 meters) using an Extron USB Extender Plus Series extension.
- Shall include backlit rubberized button panel interface.
- Device shall have a total of four soft white LED backlit buttons, dedicated for transport controls and chapter markings of a recording.
- Buttons shall feature two levels of illumination, dim and bright
- Buttons shall illuminate brightly when active, and have the ability to flash
- Record button shall feature red illumination during recording.
- Record button shall have a raised bump to allow user to located it with low visibility
- Shall include status LED indicators
- Device shall have a red and green status LED indicator for alarm and button press activity
- Device shall have a green LED for USB storage indicating:
- Off – no storage is detected, or the location is not configured.
- Green solid – Storage is detected, and the port is configured.
- Green blink – Storage is being written, or accessed.
- Shall include audible warning - buzzer.
- Device shall have an internal buzzer that sounds in conjunction with the status LED.
- Shall include a means to lock out the front panel controls.
- When enabled, the buttons flash 3 times when any one button is pressed.
- Device shall be Section 508 Compliant and shall meet or exceed accessibility standards for Electronic Information Technology
- Shall meet regulatory compliances
- Shall be certified to meet safety compliances under CE, c-UL, and UL
- Shall meet EMI/EMC compliances under CE, C-tick, FCC Class A, ICES, and VCCI
- Shall comply with requirements of RoHS and WEEE
- Shall provide three year parts and labor warranty
- Shall meet regulatory compliances
- Connection Requirements
- Approved device shall be the Extron RCP 101 (60-1598-01); no alternates or equals
RCP 101 Decorator-Style Remote Control Panel for SMP Series Products
- Provide a Decorator-style remote control panel for the purpose of remotely controlling, monitoring and connecting USB storage when paired with an Extron SMP Series Streaming Media Processor.
- Connection Requirements
- USB Requirements
- Provide one rear accessible mini USB type B port mounted at a right angle to the faceplate.
- Provide one front accessible USB type A receptacle
- Support 12V power connection
- Provide one rear captive screw connection for 12VDC power
- USB Requirements
- Mounting requirements
- Device shall have the ability to be mounted directly in a wall, lectern, or other flat surface and shall be able to be secured using the supplied mud ring and hardware.
- Device shall have the ability to be mounted to the surface of a wall using an optional wall box.
- Device shall include both white and black faceplates.
- Cabling requirements
- Device shall include a 15 foot (4.5 meters) USB A to mini B cable for direct connection to an Extron SMP series product.
- Device shall include a 15 foot (4.5 meters) DC power cable for direct connection to an Extron SMP 111 Streaming media Processor, or external 12VDC power supply
- Device may be optionally extended up to 330 feed (100 meters) using an Extron USB Extender Plus Series extension.
- Shall include backlit rubberized button panel interface.
- Device shall have a total of four soft white LED backlit buttons, dedicated for transport controls and chapter markings of a recording.
- Buttons shall feature two levels of illumination, dim and bright
- Buttons shall illuminate brightly when active, and have the ability to flash
- Record button shall feature red illumination during recording.
- Record button shall have a raised bump to allow user to located it with low visibility
- Shall include status LED indicators
- Device shall have a red and green status LED indicator for alarm and button press activity
- Device shall have a green LED for USB storage indicating:
- Off – no storage is detected, or the location is not configured.
- Green solid – Storage is detected, and the port is configured.
- Green blink – Storage is being written, or accessed.
- Shall include audible warning - buzzer.
- Device shall have an internal buzzer that sounds in conjunction with the status LED.
- Shall include a means to lock out the front panel controls.
- When enabled, the buttons flash 3 times when any one button is pressed.
- Device shall be Section 508 Compliant and shall meet or exceed accessibility standards for Electronic Information Technology
- Shall meet regulatory compliances
- Shall be certified to meet safety compliances under CE, c-UL, and UL
- Shall meet EMI/EMC compliances under CE, C-tick, FCC Class A, ICES, and VCCI
- Shall comply with requirements of RoHS and WEEE
- Shall provide three year parts and labor warranty
- Shall meet regulatory compliances
- Connection Requirements
- Approved device shall be the Extron RCP 101 (60-1598-01); no alternates or equals
RCP 101 MK mount Remote Control Panel for SMP Series Products
- Provide an MK mounting style remote control panel for the purpose of remotely controlling, monitoring and connecting USB storage when paired with an Extron SMP Series Streaming Media Processor.
- Connection Requirements
- USB Requirements
- Provide one rear accessible mini USB type B port mounted at a right angle to the faceplate.
- Provide one front accessible USB type A receptacle
- Support 12V power connection
- Provide one rear captive screw connection for 12VDC power
- USB Requirements
- Mounting requirements
- Device shall have the ability to be mounted directly in a wall, lectern, or other flat surface and shall be able to be secured using the metal faceplate and supplied hardware.
- Device shall have the ability to mount to the surface of a wall using an optional MK wall box.
- Device shall include a white faceplate only.
- Cabling requirements
- Device shall include a 15 foot (4.5 meters) USB A to mini B cable for direct connection to an Extron SMP series product.
- Device shall include a 15 foot (4.5 meters) DC power cable for direct connection to an Extron SMP 111 Streaming media Processor, or external 12VDC power supply
- Device may be optionally extended up to 330 feed (100 meters) using an Extron USB Extender Plus Series extension.
- Shall include backlit rubberized button panel interface.
- Device shall have a total of four soft white LED backlit buttons, dedicated for transport controls and chapter markings of a recording.
- Buttons shall feature two levels of illumination, dim and bright
- Buttons shall illuminate brightly when active, and have the ability to flash
- Record button shall feature red illumination during recording.
- Record button shall have a raised bump to allow user to located it with low visibility
- Shall include status LED indicators
- Device shall have a red and green status LED indicator for alarm and button press activity
- Device shall have a green LED for USB storage indicating:
- Off – no storage is detected, or the location is not configured.
- Green solid – Storage is detected, and the port is configured.
- Green blink – Storage is being written, or accessed.
- Shall include audible warning - buzzer.
- Device shall have an internal buzzer that sounds in conjunction with the status LED.
- Shall include a means to lock out the front panel controls.
- When enabled, the buttons flash 3 times when any one button is pressed.
- Device design to meet or exceed accessibility standards for Electronic Information Technology
- Shall meet regulatory compliances
- Shall be certified to meet safety compliances under CE, c-UL, and UL
- Shall meet EMI/EMC compliances under CE, C-tick, FCC Class A, ICES, and VCCI
- Shall comply with requirements of RoHS and WEEE
- Shall provide three year parts and labor warranty
- Shall meet regulatory compliances
- Connection Requirements
- Approved device shall be the Extron RCP 101 MK (60-1598-22); no alternates or equals
RCP 101 MK mount Remote Control Panel for SMP Series Products
- Provide an MK mounting style remote control panel for the purpose of remotely controlling, monitoring and connecting USB storage when paired with an Extron SMP Series Streaming Media Processor.
- Connection Requirements
- USB Requirements
- Provide one rear accessible mini USB type B port mounted at a right angle to the faceplate.
- Provide one front accessible USB type A receptacle
- Support 12V power connection
- Provide one rear captive screw connection for 12VDC power
- USB Requirements
- Mounting requirements
- Device shall have the ability to be mounted directly in a wall, lectern, or other flat surface and shall be able to be secured using the metal faceplate and supplied hardware.
- Device shall have the ability to mount to the surface of a wall using an optional MK wall box.
- Device shall include a white faceplate only.
- Cabling requirements
- Device shall include a 15 foot (4.5 meters) USB A to mini B cable for direct connection to an Extron SMP series product.
- Device shall include a 15 foot (4.5 meters) DC power cable for direct connection to an Extron SMP 111 Streaming media Processor, or external 12VDC power supply
- Device may be optionally extended up to 330 feed (100 meters) using an Extron USB Extender Plus Series extension.
- Shall include backlit rubberized button panel interface.
- Device shall have a total of four soft white LED backlit buttons, dedicated for transport controls and chapter markings of a recording.
- Buttons shall feature two levels of illumination, dim and bright
- Buttons shall illuminate brightly when active, and have the ability to flash
- Record button shall feature red illumination during recording.
- Record button shall have a raised bump to allow user to located it with low visibility
- Shall include status LED indicators
- Device shall have a red and green status LED indicator for alarm and button press activity
- Device shall have a green LED for USB storage indicating:
- Off – no storage is detected, or the location is not configured.
- Green solid – Storage is detected, and the port is configured.
- Green blink – Storage is being written, or accessed.
- Shall include audible warning - buzzer.
- Device shall have an internal buzzer that sounds in conjunction with the status LED.
- Shall include a means to lock out the front panel controls.
- When enabled, the buttons flash 3 times when any one button is pressed.
- Device design to meet or exceed accessibility standards for Electronic Information Technology
- Shall meet regulatory compliances
- Shall be certified to meet safety compliances under CE, c-UL, and UL
- Shall meet EMI/EMC compliances under CE, C-tick, FCC Class A, ICES, and VCCI
- Shall comply with requirements of RoHS and WEEE
- Shall provide three year parts and labor warranty
- Shall meet regulatory compliances
- Connection Requirements
- Approved device shall be the Extron RCP 101 MK (60-1598-22); no alternates or equals
RCP 101 EU mount Remote Control Panel for SMP Series Products
- Provide an European Union style remote control panel for the purpose of remotely controlling, monitoring and connecting USB storage when paired with an Extron SMP Series Streaming Media Processor.
- Connection Requirements
- USB Requirements
- Provide one rear accessible mini USB type B port mounted at a right angle to the faceplate.
- Provide one front accessible USB type A receptacle
- Support 12V power connection
- Provide one rear captive screw connection for 12VDC power
- USB Requirements
- Mounting requirements
- Device shall have the ability to be mounted directly in a wall, lectern, or other flat surface and shall be able to be secured using the supplied mounting bracket, spacer and hardware.
- Device shall have the ability to be mounted to the surface of a wall using an optional wall box.
- Device shall include both white and black cover plates.
- Device shall be compatible with Extron’s Flex55 mounting systems.
- Cabling requirements
- Device shall include a 15 foot (4.5 meters) USB A to mini B cable for direct connection to an Extron SMP series product.
- Device shall include a 15 foot (4.5 meters) DC power cable for direct connection to an Extron SMP 111 Streaming media Processor, or external 12VDC power supply
- Device may be optionally extended up to 330 feed (100 meters) using an Extron USB Extender Plus Series extension.
- Shall include backlit rubberized button panel interface.
- Device shall have a total of four soft white LED backlit buttons, dedicated for transport controls and chapter markings of a recording.
- Buttons shall feature two levels of illumination, dim and bright
- Buttons shall illuminate brightly when active, and have the ability to flash
- Record button shall feature red illumination during recording.
- Record button shall have a raised bump to allow user to located it with low visibility
- Shall include status LED indicators
- Device shall have a red and green status LED indicator for alarm and button press activity
- Device shall have a green LED for USB storage indicating:
- Off – no storage is detected, or the location is not configured.
- Green solid – Storage is detected, and the port is configured.
- Green blink – Storage is being written, or accessed.
- Shall include audible warning - buzzer.
- Device shall have an internal buzzer that sounds in conjunction with the status LED.
- Shall include a means to lock out the front panel controls.
- When enabled, the buttons flash 3 times when any one button is pressed.
- Device design to meet or exceed accessibility standards for Electronic Information Technology
- Shall meet regulatory compliances
- Shall be certified to meet safety compliances under CE, c-UL, and UL
- Shall meet EMI/EMC compliances under CE, C-tick, FCC Class A, ICES, and VCCI
- Shall comply with requirements of RoHS and WEEE
- Shall provide three year parts and labor warranty
- Shall meet regulatory compliances
- Connection Requirements
- Approved device shall be the Extron RCP 101 EU (60-1598-32); no alternates or equals
RCP 101 EU mount Remote Control Panel for SMP Series Products
- Provide an European Union style remote control panel for the purpose of remotely controlling, monitoring and connecting USB storage when paired with an Extron SMP Series Streaming Media Processor.
- Connection Requirements
- USB Requirements
- Provide one rear accessible mini USB type B port mounted at a right angle to the faceplate.
- Provide one front accessible USB type A receptacle
- Support 12V power connection
- Provide one rear captive screw connection for 12VDC power
- USB Requirements
- Mounting requirements
- Device shall have the ability to be mounted directly in a wall, lectern, or other flat surface and shall be able to be secured using the supplied mounting bracket, spacer and hardware.
- Device shall have the ability to be mounted to the surface of a wall using an optional wall box.
- Device shall include both white and black cover plates.
- Device shall be compatible with Extron’s Flex55 mounting systems.
- Cabling requirements
- Device shall include a 15 foot (4.5 meters) USB A to mini B cable for direct connection to an Extron SMP series product.
- Device shall include a 15 foot (4.5 meters) DC power cable for direct connection to an Extron SMP 111 Streaming media Processor, or external 12VDC power supply
- Device may be optionally extended up to 330 feed (100 meters) using an Extron USB Extender Plus Series extension.
- Shall include backlit rubberized button panel interface.
- Device shall have a total of four soft white LED backlit buttons, dedicated for transport controls and chapter markings of a recording.
- Buttons shall feature two levels of illumination, dim and bright
- Buttons shall illuminate brightly when active, and have the ability to flash
- Record button shall feature red illumination during recording.
- Record button shall have a raised bump to allow user to located it with low visibility
- Shall include status LED indicators
- Device shall have a red and green status LED indicator for alarm and button press activity
- Device shall have a green LED for USB storage indicating:
- Off – no storage is detected, or the location is not configured.
- Green solid – Storage is detected, and the port is configured.
- Green blink – Storage is being written, or accessed.
- Shall include audible warning - buzzer.
- Device shall have an internal buzzer that sounds in conjunction with the status LED.
- Shall include a means to lock out the front panel controls.
- When enabled, the buttons flash 3 times when any one button is pressed.
- Device design to meet or exceed accessibility standards for Electronic Information Technology
- Shall meet regulatory compliances
- Shall be certified to meet safety compliances under CE, c-UL, and UL
- Shall meet EMI/EMC compliances under CE, C-tick, FCC Class A, ICES, and VCCI
- Shall comply with requirements of RoHS and WEEE
- Shall provide three year parts and labor warranty
- Shall meet regulatory compliances
- Connection Requirements
- Approved device shall be the Extron RCP 101 EU (60-1598-32); no alternates or equals
把商品添加到购物车
Order Message Number
产品编号
注: 使用通用交流电源插座的 Extron 产品可支持多种不同的交流电源插头类型。在使用之前,确保设备满足您所在区域的所有规定要求,并符合所有应用的本地安全和电气规程及标准。
当前总计:
通过邮件分享该项目

RCP 101 系列
用于 SMP 系列产品的远程控制面板
请输入一个有效的邮箱地址。
谢谢。你的邮件已发送。
发送邮件时发生错误。请稍后再试。